Testo 310 II flue gas analyzer 0563 3104
- The device is able to perform both simple and more complex flue gas analyses, as well as maintenance and safety checks or determine boiler efficiency.
- Simultaneous additional measurements via the Testo Smart App (e.g. gas flow pressure, flow and ambient temperature).
- The stainless steel probe is also ideal for residential boilers.
- With different fuels (natural gas, propane, biomass 5%, firewood 20%) provides the necessary flexibility for your needs.
- Measurement data can be downloaded from the Testo Smart App.
Measures:
- O₂, CO (with built-in NOx filter), CO₂
- Undiluted CO (CO without air)
- Ambient CO
- Traction and pressure
- Temperature (flow and environment)
- Combustion / flue gas efficiency and air volume
Measuring range for flow temperature: 0...+400°C
Measuring range for ambient temperature: -20...+100°C
Accuracy for temperature in the range -20...+100°C: ±1°C
Accuracy for temperatures in the range >+100°C: ±1.5% of the measured value
Resolution for temperature: 0.1°C
Temperature response time: <50 seconds
Flue gas O₂ range: 0...21 of volume % composition
Accuracy of flue gas O₂: ±0.2 of volume % composition
Flue gas O₂ resolution: 0.1% by volume composition
Flue gas O₂ measurement response time: 30 seconds
Range of pressure difference in flue gases: -20...+20 hPa
Accuracy of the pressure difference in flue gases in the range -3...+3 hPa: ±0.03 hPa
Flue gas pressure difference accuracy in the rest of the range: ±1.5% of the measured value
Resolution of pressure difference in flue gases: 0.01 hPa
Flue gas efficiency (calculated) range: 0...120%
Flue gas efficiency resolution: 0.1%
Flue gas loss (calculated) range: 0...99.9%
Flue gas loss resolution: 0.1%
Flue gas CO₂ (calculated from O₂) range: 0...CO₂ max volume % composition (display value range)
Accuracy of flue gas CO₂: ±0.2 of volume % composition
Flue gas CO₂ resolution: 0.1% by volume composition
Flue gas CO₂ measurement response time: <40 seconds
Pressure range: -40...+40 hPa
Pressure accuracy: ±0.5 hPa
Pressure resolution: 0.1 hPa
Flue gas CO (without H₂-compensation) range: 0...4000ppm
Flue gas CO accuracy in the range 0...400ppm: ±20ppm
Flue gas CO accuracy in the range 401...2000ppm: ±5% of the measured value
Flue gas CO accuracy in the range 2001...4000ppm: ±10% of the measured value
Flue gas CO resolution: 1ppm
Flue gas CO measurement response time: 60 seconds
Ambient CO range: 0...4000ppm
Ambient CO accuracy in the range 0...400ppm: ±20ppm
Ambient CO accuracy in the range 401...2000ppm: ±5% of the measured value
Ambient CO accuracy in the range 2001...4000ppm: ±10% of the measured value
Ambient CO resolution: 1ppm
Ambient CO measurement response time: 60 seconds
Operating temperature: -5...+45°C
Storage temperature: -20...+50°C
Power supply: 1500mAh power supply unit with Micro USB output can be connected to a 230V network (included in the package)
Dimensions: 201×83×44mm
Weight: 660g (including measuring probe)
In addition to the set of silicone hoses for pressure measurements, 5 pcs. spare particulate filters and transport case.