Testo 316-2 gas leak detector with integrated pump 0632 3162
- Flexible measuring probe for hard-to-reach places.
- Short measuring interval thanks to the built-in pump.
- Both an acoustic warning signal and an 18-bar display warn of a leak.
- The 18-bar display allows more accurate determination of the gas leak concentration.
The lowest value at which the detector starts signaling: 10 ppm
Measuring range for methane (CH₄): 10 ppm to 4.0 Vol. %
First alarm limit: 200 ppm
Second alarm limit: 10000 ppm
Measuring range for propane (C₃H₈): 10 ppm to 1.9 Vol. %
First alarm limit: 100 ppm
Second alarm limit: 5000 ppm
Measuring range for H₂-containing gases: 10 ppm to 4.0 Vol. %
First alarm limit: 200 ppm
Second alarm limit: 10000 ppm
Measurement interval: <2 seconds
Heating time: 60 seconds
Operating temperature: -5...+50°C
Storage temperature: -25...+60°C
Power supply: NiMh battery (included)
Operating time with one charge: 6 h
Dimensions: 190×57×42 mm
Weight: 348g
Battery charger and headphones included.
Cart